11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
63
3. Lower the platform to the ground and
remove the pressure compensation
valve (FIG. 63-1) located at the top
of each column. Check if pressure
compensation valves are contaminated.
Disassemble, try to move plunger with
small screwdriver, and then clean each
valve if required (FIG. 63-1). Reinstall
or replace each valve if necessary.
4. Check for bent parts on the Liftgate that
could interfere with normal operation.
FIG. 63-1
FLOW CONTROL
VALVE
SCREWDRIVER
“D” VALVE (REF)
CYLINDER
(REF)
NOTE: Do the BLEEDING HYDRAULIC
SYSTEM procedure in this manual
with the following step.