11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
81
5. Check for bent and broken parts on the
Liftgate that could interfere with normal
operation.
Make sure Liftgate platform is open and resting on the ground before perform-
ing the following step.
WARNING
!
To prevent damage when installing valve cartridges & coils, torque valve
cartridge nut to 30 lbs.-in. max.
CAUTION
3. The “E” solenoid valve (FIG. 81-1) may
be stuck in the “open” position. Remove
the “E” solenoid valve (FIG. 81-2). Next,
check the valve cartridge as follows. Push
on the plunger in the valve by inserting small
screwdriver in the open end (FIG. 81-3).
If the plunger does not move with a smooth,
spring-loaded action (approximately 1/8”)
(FIG. 81-3), replace the valve cartridge.
TYPICAL SOLENOID VALVE
REMOVED & DISASSEMBLED
FIG. 81-2
COIL
VALVE
CARTRIDGE
NUT
CHECKING VALVE CARTRIDGE
FIG. 81-3
VALVE
CARTRIDGE
1/8”
4. Reinstall “E” solenoid valve (if good)
(FIG. 81-2) or a replacement. Torque
valve cartridge to 30 lbs.-ft. and hex
nut to 30 lbs.-in.
POWER DOWN PUMP
FIG. 81-1